Colocation and data centre services in Nicosia, Cyprus
Logosnet DataFort is a carrier-neutral data centre in Nicosia, Cyprus, built for businesses that need secure, always-on hosting for their IT equipment.
The facility meets European data centre specifications and is monitored monthly by BT Group, one of the world’s largest communications providers, with whom Logosnet has a long-standing partnership.
Colocate your mission-critical equipment with us for reliable IT service continuity. Our infrastructure is fully redundant, with proven disaster recovery systems in place.
Logosnet DataFort, Nicosia, Cyprus
Cold aisle containment separates hot and cold air flows. In-row cooling and more than 75 temperature measurement points keep both cooling and IT equipment running reliably.
An air filtration system keeps DataFort clean, and iCooling intelligent optimisation cuts cooling energy use by up to 20%.
Power redundancy: online UPS and diesel generators take over within 45 seconds of a power cut, with 99.99% power uptime.
Direct connection to our bandwidth: cabling runs under the floor from our telecom rack straight to yours. Safe, secure and fast.
Earthquake-resistant raised floor, 60 cm high, rated to 1,500 kg/m².
Access control, 24/7 CCTV monitoring, security alarms and an automatic fire extinguishing system protect the room and your equipment.
An on-site workspace in the same building gives you easy access to your equipment.
DataFort is supervised by our Head IT Manager, Dr Michalis Michael, President of CyIX (the Cyprus Internet Exchange), who has extensive experience in consulting on, installing and configuring customer equipment.
Security
- Total security and facilities management
- Physical security of premises
- A secured rack environment
- Lockable rack cabinets
- Regulated power supply
- Three-phase power with N+1 UPS (lithium batteries)
- N+1 redundant 500 kVA diesel backup generators
- Redundant HVAC systems
- Smoke, temperature, humidity and air quality detection
- Fire detection system
- High-grade Inergen fire extinguishing system
- Heavy-duty, anti-static, fireproof raised flooring and gates
- Climate-controlled, with automated temperature and humidity management
- 24/7 video surveillance
- 24/7 access control
- 24/7 alarm monitoring
- Security personnel
- Intelligent refrigerant leak detection prevents loss of cooling capacity and air-conditioner breakdowns
- Wet-film humidification uses 95% less energy than traditional electrode humidifiers
Availability
- Carrier-neutral: scalable bandwidth with direct connections to the backbones of all local fibre-optic network operators (CYTA, PrimeTel, Epic, Cablenet) and major international carriers
- 99.99% network availability guaranteed
- 99.99% power uptime guaranteed
- 24/7 system monitoring and NOC support
- Strong SLAs
Flexibility
- 1U to 20U of rack space in a shared standard rack
- Full 42U standard rack
- Cage colocation: a dedicated cage with mechanical lock and restricted access
- Suite colocation: fully enclosed, custom-built colocation suites
- Power distribution design and installation
- Colocation infrastructure design and consulting
- Project management to get your caged colocation area up and running
- Scalable bandwidth for network interconnections and internet services
- Remote hands and eyes support
- Workspace for customers when needed
Frequently asked questions
Where is the Logosnet DataFort data centre?
DataFort is in Nicosia, Cyprus.
Is DataFort carrier neutral?
Yes. DataFort connects directly to the backbones of all local fibre-optic network operators (CYTA, PrimeTel, Epic and Cablenet) and to major international carriers.
What colocation options are available?
From 1U to 20U in a shared rack, a full 42U rack, a dedicated cage with mechanical lock and restricted access, or a fully enclosed custom-built suite.
What uptime is guaranteed?
99.99% network availability and 99.99% power uptime, backed by strong SLAs and 24/7 monitoring and NOC support.
How is power kept running during an outage?
Three-phase power with N+1 UPS on lithium batteries, plus N+1 redundant 500 kVA diesel generators that take over within 45 seconds of a power cut.
How is equipment protected from fire?
Smoke, temperature, humidity and air quality detection, a fire detection system and a high-grade Inergen fire extinguishing system.
Do you offer remote hands?
Yes. Remote hands and eyes support is available, and there is an on-site workspace for customers when needed.